Abstract

The National Building Code of Canada 2015 stipulates the minimum requirements of the airborne sound insulation transmission through common interior walls and ceiling/floor assemblies. The required minimum Apparent Sound Transmission Class (ASTC) is 47 in Canada, whereas the Impact Insulation Class (IIC) for floors is recommended to be higher than 55. For many years, significant efforts were made to develop sound insulation prediction models or tools to predict the sound insulation performance of wall and floor/ceiling assemblies at the design phase in order to meet the requirements and the recommendations made by codes. However, today few models can provide a reliable acoustics design tool. In this document, three prediction tools thought to be practically useful are presented and evaluated. Between these three prediction tools, one is an analytical model of the Insul software while the other two are empirical models developed by the National Research Council of Canada and the American Wood Council. This paper compared the STC and IIC ratings of wood wall and floor assemblies estimated by these three models and verified them by the measured STC and IIC ratings. This work aims at providing an idea for readers to choose a suitable design tool to proceed with their acoustic designs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call