Abstract

This study investigated changes in voice quality after thyroplasty type I in eight adults with unilateral vocal fold paralysis. A silicone rubber implant was inserted through a window in the thyroid ala and placed between the inner and outer perichondrium to externally medialize the abducted vocal fold. Measures of fundamental frequency (vocal pitch), pitch range, maximum phonation time, s/z ratio, pitch perturbation (vocal jitter), and amplitude perturbation (vocal shimmer) were made 1 to 2 weeks preoperatively and 1 month postoperatively. Postoperative voice quality was characterized by an improved pitch range, phonation time, s/z ratio, and pitch and amplitude perturbation. No change was noted in fundamental frequency. Changes in postoperative voice quality were unrelated to the subjects' preoperative age, sex, etiology, and duration of the paralysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.