Abstract

The acid hydrolysis of proteins was miniaturized and simplified by employing microcapillary tubes (100 microl in volume) with 6 M HCl containing 1% 2-mercaptoethanol and 3% phenol for an amino acid compositional analysis. The method not only eliminated the laborious evacuation step for the hydrolysis tube but also decreased the destruction of tryptophan during hydrolysis. The recovery of tryptophan was 79% by acid hydrolysis at 145 degrees C for 4 h. Since the acid mixture could be removed under vacuum, the hydrolysate was subjected to an amino acid analysis without neutralization or dilution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.