This paper introduces a novel on-line real-time monitoring system for acidic emission produced by acid pickling, which has been one of the greatest contaminant and major harness content. The system can monitor the HCL concentration in exhaust fumes on-line, and realize the real-time analysis and transmission of the acquisition data. HCL wet chemical sampling system form the whole on-line monitoring system. HCL wet chemical sampling system consists of integrated air velocity transducer, chloride ion analyzer, wet chemical sampling device and liquid level measurement device. It aims to collect HCL fog sample and convert the sampling analogue signal to digital data that can be analyzed. The system overcomes the influence by high temperature, high humidity and high concentration of dust. It realizes the monitoring, storage, analysis, warning and transmission of HCL concentration data in the exhaust. It is beneficial in practical industrial field and environmental protection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.