Abstract

Human IgM and IgG antibodies against blood group antigens (A, B, D, C, c, E, e, Fy^a, K), autoantibodies and mouse IgM and IgG antibodies against sheep erythrocytes have been eluted from intact human and sheep red cells by glycine-HCl buffer, pH 3.0. The yield of human antibodies was higher with acid than with heat and ether elution, and the contamination of hemoglobin in the eluate was negligible. The acid elution method is very simple and rapid and, therefore, highly suitable for experimental as well as routine immunohematological work.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.