Abstract

Acids generated upon exposure to radiation induce the polarity change of the polymer through catalytic chain reactions in chemically amplified resists. With the reduction of feature size, the acid diffusion length increasingly becomes an important issue. In this study, we investigated the acid diffusion length in line-and-space patterns fabricated using a small field exposure tool for extreme ultraviolet (EUV) lithography and the EIDEC standard resist to clarify the acid diffusion length in a state-of-the-art resist. The acid diffusion length depended on the nominal line width and exposure dose. Upon exposure to EUV radiation with an exposure dose of 16 mJ cm-2, the acid diffusion length (three-dimensional) in a line-and-space pattern with 21 nm nominal line width was 9.5 nm.