Abstract

Background and objective Patellarfractures account for around 1% of all fractures. Conservative treatment is advised in patients without any incompatibility of articular surfaces or those with intact extensor mechanisms. More than a 2-mm articular gap due to fracture warrants surgical intervention. Tension band wiring (TBW) is a commonly used practice for fixation, However, there is still controversy about its effectiveness and complications arising due to the hardware. Modification of this technique by using K-wires has been considered a method of choice, but this technique is associated with complications due to K-wires. The Pyrford technique is a method for patellar fracture fixation by circumferential cerclageand anterior TBW. We employed the figure-of-eight configuration over the circumferential wire. This study aimed to analyze the outcomes ofTBW of the patella without K-wires by assessing the rate of complication and functional outcomes. Materials and methods A total of 38 patientswithOTA 34C type, simple and comminuted type of patella fractures aged between22 and 70 years were treated with circumferential cerclage and figure-of-eight TBW.All patients underwent patellar fixation with cerclage and through direct purchase of SS wire via quadriceps and patellar tendon. Patients were followed up for one to three years. We analyzed differences in the range of motion, fracture reduction, fracture healing time, Bostman score for knee function, and complications. Results The mean age of the patients was 45 years. After TBW without K-wires, fracture healing and functional outcomes were satisfactory according to patient feedback and clinocoradiological examinations. Of note, 35 out of 38 patients (92%) had gained up to 90 degrees of active flexion at the end of one week. One patient (2.42%) developed a superficial infection. All fractures had achieved union at the end of 16 weeks. Malunion or nonunion was not noted in any of the cases. There was no case of implant removal. The average Bostman score at the 12-month follow-up was 28.5 ±1.5. The incidence of complications due to K-wire was nullified. Conclusion Based on our findings, the described method leads to better functional outcomes, decreasing hardware-related complications, and can be used in simple as well as comminuted fractures. The fracture healing and functional outcomes and rate of complications were satisfactory.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call