Abstract
Total knee arthroplasty patients often have difficulty performing activities involving flexion beyond 130°. The NexGen LPS Flex (Zimmer Inc, Warsaw, Ind) mobile bearing implant accommodates up to 155° of flexion. Two hundred eighteen total knee arthroplasties were performed using this implant on 125 patients over a 2-year period with a minimum of 5 years follow-up. All data were collected prospectively. Forty-four percent of preoperative cases had full flexion (ie, 140° active flexion and ability to kneel with thigh/calf contact for 1 minute). Five-year data showed an average flexion of 140° ± 11.5° and flexion greater than 140° in 103 knees (68%). There were no differences in patellofemoral pain levels, complications, or Knee Society scores despite our patients having, on average, an increase in flexion and function.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.