Abstract

A radio frequency (RF) ion source was developed for neutral beam injector in Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). A cylindrical driver based RF plasma source was tested and optimized for long pulse operation. Recently, the plasma source achieved 1000 s stable plasma discharge with RF power of 35 kW and source pressure of 0.7 Pa for the first time. The heat loading on each of driver components such as the Faraday shield (FS), RF coil and expansion chamber was measured by the water flow calorimeter system. The experiment results showed that FS is the component with highest heat loading and the heat loading on FS was about 65.8% of total heat loading on source. The details of the long pulse operation of RF plasma source are presented in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.