Abstract

Background: This study was aimed at evaluating the changes in cup coverage (CC) and hip center of rotation (HCOR) in acetabular defects of various severities treated with acetabular revision using jumbo cups. Methods: A total of 86 hips were included. The American Academy of Orthopedic Surgeons (AAOS) classification of these patients was as follows: 16 patients, AAOS I; 16 patients, AAOS II; and 16 patients, AAOS III. A three-dimensional (3D) implant simulation technique was used to visualize the placement of jumbo cups during revision arthroplasty. The acetabular anteversion, inclination, CC, and the HCOR were measured. Results: The inclination and anteversion of simulated acetabular cups in AAOS I–III groups were consistent with the normal acetabular anatomy. Compared with the controls, in AAOS I–III groups, the HCOR was significantly increased and CC was significantly decreased. The HCOR elevation was significantly higher in AAOS III patients than in AAOS I (p = 0.001) and AAOS II patients (p < 0.001). The use of the jumbo cup technology for acetabular revision would decrease the CC in AAOS I–III patients to 86.47, 84.78, and 74.51%, respectively. Conclusion: Our study demonstrated that in patients with acetabular defects, acetabular revision arthroplasty using jumbo cups will lead to decreased CC and HCOR upshift. Upon classifying these patients according to the AAOS classification, CC decreased with the severity of acetabular defects, and the elevation of the HCOR in AAOS III patients exceeded 10 mm and was significantly higher than in other patients.