Abstract

Single-phase inverters have a wide range of applications in many fields, but there are inherent double frequency problems, and double frequency fluctuations can easily cause system instability. This paper proposes a mid-point common-mode injection power decoupling circuit. The advantage of this topology is that there are no additional switching devices and only the original DC side support capacitors and filter capacitors of the H-bridge inverter can be used to buffer the double frequency power. The half-bridge structure of this topology enables the AC side capacitors to operate positively and negatively, which can reduce the selection of the withstand voltage of the decoupling capacitor. Simulation and experimental results prove that the method can effectively suppress the secondary ripple on the DC side. The final data shows that the topology can effectively improve the system efficiency after decoupling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.