Abstract

Compressor piping is a dominant noise source in petrochemical plants with large centrifugal compressors. Acoustic insulation is used on compressor suction, discharge and recycle lines as a measure to mitigate noise radiating from compressor piping. This paper will demonstrate using case studies the importance of acoustic insulation on compressor piping as the primary and most cost effective noise control method for both community and in-plant noise. Case studies include the predicted and measured noise levels obtained during post startup noise surveys. This paper will also illustrate that to obtain good agreement with measured noise levels it is imperative to accurately model the piping sources following the actual piping layout and account for distance attenuation. A cost-benefit analysis of using complete compressor houses and/or acoustic blankets will be presented along with the efficacy of various types of acoustic insulation including elastomeric foam and aerogel based insulation systems. Different acoustic requirements for hot and cold insulation systems will also be presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.