Abstract

In this paper procedures for estimating the sound absorption coefficient when the specimen has inherently low absorption are discussed. Examples of this include the measurement of the absorption coefficient of pavements, closed cell foams and other barrier materials whose absorption coefficient is nevertheless required, and the measurement of sound absorption of muffler components such as perforates. The focus of the paper is on (1) obtaining an accurate phase correction and (2) proper correction for tube attenuation when using impedance tube methods. For the latter it is shown that the equations for tube attenuation correction in the standards underestimate the actual tube attenuation, leading to an overestimate of the measured absorption coefficient. This error could be critical, for example, when one is attempting to qualify a facility for the measurement of pass-by noise. In this paper we propose a remedy – to measure the actual tube attenuation and to use this value, as opposed to the value recommended by the standards, to correct the measured sound absorption. We also recommend an alternative way to determine the microphone phase error.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.