Abstract
Moiré interferometry is a very sensitive optical method to measure the in-plane displacement of a solid specimen, and is useful to measure small deformation of solids. But, there often appears measurement error caused by the residual strain of the grating that is pasted on a specimen in Moiré interferometry. The present paper applies a method to eliminate the error brought by the residual strain of the grating. The method measures the change of the order of Moiré interference fringes with varying the tensile force applied to the specimen, and obtain the true opening displacement of the notch. The present paper uses the method mentioned above to measure the opening displacement of a bifurcated notch in a plate specimen
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.