Abstract

Traumatic lung injury (TLI), which is a common mechanical injury, is receiving increasing attention because of its serious hazards. In forensic practices, accurately identifying TLI is of great importance for investigations and case trials. The main goal of this research was to identify TLI utilizing attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy in combination with chemometrics. The macroscopic appearance of lung tissue showed that identifying TLI in lung tissue at the decomposition stage is not feasible by only visualization, and significant pulmonary hypostasis was observed in the lungs regardless of whether the lung tissue was injured. Average spectra and principal component analysis (PCA) suggested that the biochemical difference between injured lung tissue samples from the TLI group and noninjured lung tissue samples from the negative control group was mainly attributed to the different structures and contents of proteins. Partial least squares discriminant analysis (PLS-DA) was then utilized to identify TLI with an accuracy of 96.4% and 98.6% based on the training set and the test set, respectively. Next, we focused on samples that were misclassified in the model and proposed that the misclassification could be caused by the pulmonary hypostasis effect. Therefore, two additional PCA and PLS-DA models were created to identify the pulmonary hypostatic areas between the TLI group and the negative control group and the nonpulmonary hypostatic areas between the TLI group and the negative control group. The PCA results indicated that the biochemical difference between the two groups was still associated with proteins, and the two PLS-DA models achieved 100% accuracy based on both the training and test sets. This result indicated that when pulmonary hypostasis was considered and the lung tissue was divided into pulmonary hypostatic areas and nonpulmonary hypostatic areas for separate comparisons, TLI identification was achieved with a greater accuracy than that obtained when the two areas were combined. This research confirms that the combined application of ATR-FTIR spectroscopy and chemometrics can be utilized to accurately identify TLI.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.