Abstract

IntroductionPlasma is considered the gold standard for HIV viral load (VL) testing, however its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed a rapid expansion of antiretroviral therapy (ART) monitoring in remote areas in many African countries, however, the VL in DBS may overestimate the copies of viral RNA result at the clinically relevant range of 1000 copies/ml, due to proviral DNA and intracellular RNA. The characteristics of the cobas® Plasma Separation Card (PSC) specimen are similar to fresh plasma (gold standard), so a better performance of HIV VL is expetected in PSC specimen and can be an alternative to DBS. This study aims to evaluate the performance of cobas® PSC for VL testing at primary health care facilities in Mozambique.MethodologyHIV-1 infected adults on ART were enrolled consecutively in two health facilities in Mozambique, between August 2018 and October 2018. Capillary and venous cobas® PSC, DBS and fresh plasma specimens were collected from each patient. All specimens were tested for VL using CAP/CTM v2.0. Sensitivity and specificity of viral load using DBS, capillary and venous PSC specimens were estimated. Viral load obtained in fresh plasma specimen was used as reference and a threshold of 1000 copies/ml was considered for the analyses.ResultsFrom the total 613 patients included for the study, 2444 specimens including DBS (613), plasma (613), venous cobas® PSC (609) and capillary cobas® PSC (609) were collected and 2407 results were obtained. Sensitivity and specificity of the VL using venous cobas®PSC specimen at 1000 copies/ml threshold were 99.8% and 98.1% respectively, whereas for capillary cobas® PSC sensitivity was 99.6% and specificity was 97.2%. For DBS VL, sensitivity was 96.9% and specificity was 81.8%. Misclassification rate was more prominent in DBS specimens (5.9%), but lower in venous and capillary cobas®PSC with a rate of 0.3% and 0.7% respectively.ConclusionThe cobas® PSC specimen has improved performance over DBS for more accurate VL testing aligned with plasma testing. The use of this specimen type can increase the rates of reliable VL results and this will improve the quality of VL monitoring of HIV-positive patients in low-income settings.

Highlights

  • Plasma is considered the gold standard for HIV viral load (VL) testing, its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing

  • The cobas® Plasma Separation Card (PSC) specimen has improved performance over Dried Blood Spot (DBS) for more accurate VL testing aligned with plasma testing

  • HIV viral load determination is best achieved in fresh plasma specimens, with viral RNA quantification performed in laboratories using sophisticated equipment

Read more

Summary

Introduction

Plasma is considered the gold standard for HIV viral load (VL) testing, its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed a rapid expansion of antiretroviral therapy (ART) monitoring in remote areas in many African countries, the VL in DBS may overestimate the copies of viral RNA result at the clinically relevant range of 1000 copies/ml, due to proviral DNA and intracellular RNA. The characteristics of the cobas® Plasma Separation Card (PSC) specimen are similar to fresh plasma (gold standard), so a better performance of HIV VL is expetected in PSC specimen and can be an alternative to DBS. This study aims to evaluate the performance of cobas® PSC for VL testing at primary health care facilities in Mozambique

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.