Abstract

Children are at increased risk of medication-associated adverse events, often due to weight-based dosing errors. We aimed to reduce the proportion of medications that were administered where the dosing weight was ≥ 10% different from the recorded weight. We adopted in-situ usability testing to iteratively improve design of clinical decision support that would enable accurate dosing weight documentation by prompting clinicians to update weight if recorded weight was > 10% different and it had been at least 7 days since the last dosing weight update. The proportion of medication administrations with difference >10% between their recorded weight and dosing weight decreased from 13.1% (56,256/ 429,006) in the baseline period to 9.5% (35,560 / 372,443) in the intervention period (P < 0.001). User-centered design of an interruptive alert improved the accuracy of dosing weights during medication administrations without substantial alert burden. In-situ usability testing is an effective approach to rapidly obtain feedback from frontline users and iterate on the design to effect desired behavior changes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call