Abstract

Leakage inductance is an important parameter in a high-frequency transformer for its influence on power transmission performance and the soft switching of converters. Nowadays, Litz wire is widely used to control winding loss and reach high efficiency. However, it is not an easy task to accurately calculate its leakage inductance. This article presents a detailed model of leakage energy in Litz wire, and proposes an accurate closed-form expression for calculating the leakage inductance in a high-frequency transformer. The skin effect and the proximity effect of Litz wire are taken into account in two-dimensional polar coordinates, and the filling factor of Litz wire is also considered. A global sensitivity analysis is performed to assess the influence of each parameter on the overall leakage inductance. Finally, two transformer prototypes are made to verify the accuracy of the proposed analytical expression.

Full Text