Abstract

IntroductionThe Broselow tape (BT) is a useful pediatric tool for weight estimation and dosing reference during emergency care. Many accuracy studies have been performed for various countries and regions of the world but there is very little information for Latin American countries. The primary objective of the study was to assess the accuracy of the BT in a Peruvian pediatric population.MethodsThis was a retrospective cross-sectional study of 1,160 children aged two to 19 years from three outpatient clinics in La Libertad, Lima, and Iquitos, Peru. Patient height and weight were measured and compared with the weight and color zone generated by the 2017 edition of the BT. Accuracy was estimated by statistical comparison of mean absolute percent differences, error within 10% (EW10), and color zone agreement.ResultsComparison of mean differences between measured weight (MW) and estimated BT weight shows that the BT underestimates actual weight for all color zones in this population. Likewise, the Bland-Altman plot of agreement between estimated and measured weights shows an overall underestimation, or bias, equal to 1.60 kg. The overall percent difference was -7.84% with differences gradually increasing for weights over 10 kg. In terms of accuracy, the overall error within 10% was 62.8%.ConclusionThe BT underestimates the actual weight of Peruvian pediatric patients in all color categories, particularly in children with higher body mass indexes. Underestimation of weight may lead to the use of non-therapeutic medication doses or incorrect equipment sizes and, subsequently, ineffective resuscitation.

Highlights

  • ObjectivesThe primary objective of the study was to assess the accuracy of the Broselow tape (BT) in a Peruvian pediatric population

  • The Broselow tape (BT) is a useful pediatric tool for weight estimation and dosing reference during emergency care

  • The primary objective of the study was to assess the accuracy of the BT in a Peruvian pediatric population

Read more

Summary

Objectives

The primary objective of the study was to assess the accuracy of the BT in a Peruvian pediatric population

Methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.