Abstract
Our aim was to test the effectiveness of ultrasound-guided intra-articular (IA) injection into the knee joint of rodents by an inexperienced operator compared with standard landmark-guided IA injections by a trained injector. Fifty landmark-guided and 46 ultrasound-guided IA injections in 49 rats were analyzed. Animal positioning and injection protocol were designed for use with the ultrasound system. Injection delivery was verified with a secondary imaging modality. We compared the success of IA injections by method (landmark and ultrasound-guided), adjusting for all other confounding factors (age, weight, experience, laterality and presence of surgery). Ultrasound-guided injections had higher success rates overall (89% vs. 58%) and helped to reduce the number of failed attempts per injection. None of the cofounding factors influenced the success of injection. In conclusion, we found higher accuracy for ultrasound-guided IA injection delivery than the traditional landmark-based injection method and also the technical feasibility for untrained personnel.
Accepted Version
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.