Abstract

Most small-signal calculations of the modulation in a klystron's gain cavity use an equivalent circuit which includes a fixed beam impedance. Comparing this calculation to the gain calculated self-consistently, we note there are appreciable errors in both the calculated amplitude and phase of the cavity's modulation. These errors may lead to large accumulated errors in determining either the tube's small-signal or large-signal gain. Both techniques are used in a comparison with an existing S-band klystron.