Abstract

Purpose The practical value of ultrasonography as a rapid means to determine accurately residual urine volume was assessed. Materials and Methods Transverse and sagittal bladder diameters, as well as areas from longitudinal and transverse images, were measured with real-time ultrasonography in 324 men immediately after voiding. Calculated bladder volumes using measured diameters and areas for each of 11 formulas in the literature were compared to the corresponding measured total residual urine volumes. Results The lower limit of ultrasonographic visualization of urine in bladder was approximately 48 ml. No correlation existed between ultrasound calculated bladder volumes and measured residual urine for any of the 11 formulas. Conclusions Ultrasonography cannot rapidly measure bladder volumes accurately to date. Catheterization remains the most accurate method of assessing post-void residuals but in many cases it may not be the best approach to patient care.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.