Abstract

BackgroundThe aim of the study was to compare the accuracy of percutaneous pedicle screw (PPS) insertion (P-side) with that of conventional open screw insertion (O-side) during unilateral open transforaminal lumbar interbody fusion (TLIF) in the same patients. We also sought to determine the incidence of pedicle screw misplacement and to identify relevant risk factors.MethodsThe study was a retrospective analysis of prospectively collected data for 766 pedicle screws placed in 181 consecutive patients who underwent a unilateral open-TLIF procedure in the lumbosacral spine. Our minimally invasive TLIF was performed by unilateral open freehand insertion of pedicle screws for decompression on one side and PPS on the opposite side. Using this approach, we were able to compare the accuracy of PPS insertion with that of conventional open screw insertion in the same patients. There were 383 PPSs and 383 screws inserted by the open method. The accuracy of screw placement was evaluated on reconstructed computed tomography images obtained postoperatively, and screw misplacement was classified. Potential risk factors for screw misplacement were investigated in three-level mixed-effects logistic regression analysis.ResultsThirty-four screws (8.9%) were misplaced on the P-side and 37 (9.5%) were misplaced on the O-side; the difference was not statistically significant (P = 0.803). Subclassification analysis revealed minor perforation of 28 screws (7.3%) on the P-side and 32 (8.4%) on the O-side, moderate perforation of 5 screws (1.3%) on the P-side and 4 (1.0%) on the O-side, and severe perforation of 1 screw (0.3%) on each side. Three-level mixed-effects logistic regression analysis identified body mass index as a significant risk factor for screw misplacement on the P-side (odds ratio 1.194, 95% confidence interval 1.066–1.338).ConclusionsAccuracy of pedicle screw insertion was not significantly different between PPS insertion and conventional open screw insertion in the same patients. Body mass index had a significant influence on the risk of screw misplacement in PPS insertion.

Highlights

  • The aim of the study was to compare the accuracy of percutaneous pedicle screw (PPS) insertion (Pside) with that of conventional open screw insertion (O-side) during unilateral open transforaminal lumbar interbody fusion (TLIF) in the same patients

  • Body mass index had a significant influence on the risk of screw misplacement in PPS insertion

  • Pedicle screws are used for Minimally invasive surgery (MIS)-TLIF but must be inserted correctly because misplacement can lead to devastating complications

Read more

Summary

Introduction

The aim of the study was to compare the accuracy of percutaneous pedicle screw (PPS) insertion (Pside) with that of conventional open screw insertion (O-side) during unilateral open transforaminal lumbar interbody fusion (TLIF) in the same patients. Some previous studies have investigated the accuracy of pedicle screw insertion [5, 6] and compared percutaneous pedicle screw (PPS) insertion with insertion using the conventional open technique [7, 8]. Some studies have found that the accuracy of PPS insertion is better than that of conventional open insertion [9,10,11,12], but other studies have found no significant difference [7, 8] These studies did not examine the techniques through side-by-side comparison in the same patients. Several causes of pedicle screw misplacement have been identified [5, 6]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call