Abstract
The commonly recommended one-dimensional (ID) and two-dimensional (2D) algorithms for left ventricular (LV) mass calculation are limited by assumptions about ventricular geometry and image plane position. To assess the accuracy of these algorithms after eliminating errors associated with image plane position, LV mass was calculated from high quality cardiovascular magnetic resonance imaging (CMR) data sets using ID (modified cube formula; MCF) and 2D algorithms [area-length (AL) and truncated ellipsoid (TE) methods], and the summation of slices (SS) method as reference technique in 25 patients with LV aneurysms, 15 patients with hypertrophic cardiomyopathy, and 10 healthy subjects. Each algorithm in each group overestimated LV mass compared to SS (p <0.05 and p<0.001). In each patient group, the smallest bias to the reference method was observed for the TE algorithm (p<0.001 vs. MCF and p < 0.05 vs. AL). The LV mass interval encompassing the limits of agreement was 120-220 g for MCF, 100-148 g for AL, and 80-136 g for TE. The interstudy reproducibility of the SS technique for the assessment of LV mass was superior compared to the ID and 2D algorithms. We conclude that despite the use of optimized image plane position ID and 2D algorithms are inaccurate for calculation of LV mass in ventricles with normal and distorted LV geometry. Thus, 3D imaging techniques, such as CMR, should be preferred when assessing LV mass.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.