To The Editor: The article entitled “Accuracy of Needle Placement into the Intra-Articular Space of the Knee” (2002:84:1522-7), by Jackson et al., describes an interesting, well-thought-out, and well-executed study. It demonstrates the difficulty of accurately placing a needle into the intra-articular space when an effusion is not present. However, during my fellowship with Richard B. Caspari, MD, injection techniques were taught and the highest accuracy of anteromedial or anterolateral needle placement was not accomplished with the knee hanging freely at approximately 90° but rather with the knee flexed only about 30° and supported on a foam rest. … Corresponding author:, Douglas W. Jackson, MD, Orthopaedic Research Institute at the, Southern California Center, for Sports Medicine, 2760 Atlantic Avenue, Long Beach, CA 90806, simori{at}aol.com
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of bone and joint surgery. American volume
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.