Abstract

BackgroundLeg length discrepancy is one of the most common problems after total hip arthroplasty (THA). The aim of this study was to investigate the accuracy of image-free navigation in intraoperative leg length change (LLC) using evaluations from anteroposterior radiographs (2D measurement) and 3D bone models using CT data (3D measurement).MethodsOne hundred THAs with cementless cups and stems were performed using an image-free navigation system in our hospital. We evaluated the accuracy of image-free navigation based on LLC from 2D and 3D measurements. Furthermore, we also investigated error in absolute value and correlations between 2D and 3D measurements in LLC.ResultsThe accuracy of image-free navigation based on 2D measurement was 94% within 5 mm and 76% within 3 mm. The accuracy of image-free navigation based on 3D measurement was 92% within 5 mm and 81% within 3 mm. The error in absolute value in LLC between 2D and 3D measurements was 1.7 ± 1.4 mm (range, 0 to 6 mm). A strong correlation was observed between 2D and 3D measurements in the LLC.ConclusionsIn the present study, good accuracy of image-free navigation in intraoperative LLC was confirmed for both evaluation methods from 2D and 3D measurements. In addition, the error in absolute value in the LLC between 2D and 3D measurements was very small, and we observed a strong correlation between 2D and 3D measurements. Based on these results, evaluation of LLC from radiographs was considered sufficient if radiographs can be taken accurately.

Highlights

  • Leg length discrepancy is one of the most common problems after total hip arthroplasty (THA)

  • We investigated the error in absolute value and the correlation between 2D and 3D measurements of leg length change (LLC)

  • Intraoperative LLC with image-free navigation was significantly shorter than LLC on 2D and 3D measurements

Read more

Summary

Introduction

Leg length discrepancy is one of the most common problems after total hip arthroplasty (THA). The aim of this study was to investigate the accuracy of image-free navigation in intraoperative leg length change (LLC) using evaluations from anteroposterior radiographs (2D measurement) and 3D bone models using CT data (3D measurement). Leg length discrepancy (LLD) is one of the most common problems after total hip arthroplasty (THA). A three-dimensional (3D) method based on 3D bone models from computed tomography (CT) data has been used for preoperative and postoperative evaluation of total joint arthroplasty. No reports appear to have compared between the 2D and 3D measurements for the accuracy evaluation of image-free navigation. The aim of this study was to investigate the accuracy of image-free navigation in intraoperative LLC using evaluation methods based on 2D and 3D measurements

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call