Abstract

This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS) material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1) one-step; two-step relief with: (2) PVC film; (3) slow-speed tungsten carbide bur and scalpel blade, (4) small movements of the tray and (5) without relief—negative control. The impressions were disinfected with 0.5% sodium hypochlorite for 10 minutes and stored during 110 and 230 minutes for the first and second pouring, respectively, with type IV gypsum. Three intra-oral lateral photographs of each patient were taken using a tripod and a customized radiographic positioner. The images were imported into ImageJ software and the total area of the buccal surface from teeth #13 to #16 was measured. A 4.0% coefficient of variance was criterion for using these measurements as Baseline values. The casts were photographed and analyzed using the same standardization for the clinical images. The area (mm2) obtained from the difference between the measurements of each gypsum cast and the Baseline value of the respective patient were calculated and analyzed by repeated-measures two way-ANOVA and Mauchly’s Sphericity test (α = 0.05). No significant effect was observed for Impression technique (P = 0.23), Second pouring (P = 0.99) and their interaction (P = 0.25). The impression techniques and double pouring did not influence the accuracy of the gypsum casts.

Highlights

  • An accurate and dimensionally stable impression is an essential step for manufacturing wellfitting indirect restorations [1]

  • This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring

  • No significant effect was observed for Impression technique (P = 0.23), Second pouring (P = 0.99) and their interaction (P = 0.25)

Read more

Summary

Introduction

An accurate and dimensionally stable impression is an essential step for manufacturing wellfitting indirect restorations [1]. One of them is the lowest permanent deformation [2], making it dimensionally stable for up to two weeks and able to be disinfected without loss of accuracy [3], in addition to the high tear resistance, neutral odor and taste. Casts’ Accuracy after Different Impressions and Double Pouring accuracy of an impression/cast is obtained with custom trays, the use of stock trays for elastomeric impressions is very usual [4] because it is an economic and simple procedure. Some authors [5] show that the impression tray type does not affect the accuracy of final casts. Several studies [1,6,7,8,9,10,11,12] discuss pro’s and con’s of different impression techniques, there being no consensus among them regarding the choice of the ideal method for such a clinical problem

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.