Abstract

ObjectivesTo investigate the complete arch accuracy of intraoral scanners (IOS) on two different ceramic surfaces. MethodsTwo maxillary master cast samples were prepared. The bases of both the master casts were made from zirconium oxide. The difference between the two casts was that the teeth of the [ZR] cast were produced from zirconium oxide and that of the [LD] cast were made of lithium disilicate glass-ceramic. Unlike the zirconia teeth of the [ZR] cast, the lithium disilicate teeth of the [LD] cast were glazed. The two master casts were digitized using a high-resolution scanner (Atos Compact Scan 5 M, GOM GmbH, Braunschweig, Germany) to obtain digital reference casts. Subsequently, each master cast was scanned 15 times using four IOSs. The IOSs were the Cerec Omnicam [OM], Primescan [PR], Trios 4 [TR4], and VivaScan [VS]. On surface comparison, the absolute mean deviation values were obtained for trueness and precision. For multiple comparisons, statistically significant differences were analyzed using one-way ANOVA and the Kruskal-Wallis H test. The p-value was adjusted to control for the increased risk of type I error (p < 0.0083). To compare the two means, the t-test and Mann-Whitney U test were used (p < 0.05). ResultsTrueness values for [ZR] ranged from 24.6 (±6.3) µm for [PR] and 77.1 (±8.3) µm for [OM]. Trueness values for [LD] were between 28.3 (±6.3) µm for [PR] and 72.8 (±15.6) µm for [OM]. Precision values for [ZR] ranged from 17.6 (±3.7) µm for [PR] to 37.3 (±9.9) µm for [OM]. Precision values for [LD] ranged from 17.5 (±3.6) µm for [PR] to 41.8 (±8.7) µm for [OM]. Statistically significant differences were found among all the IOSs (p < 0.0083). The trueness values of the four IOSs did not differ significantly (p < 0.05) with respect to either the [ZR] or [LD] cast. The precision values of [OM] and [VS] differed significantly with respect to the scanned surface. ConclusionsComplete arch scans achieved with the four IOSs showed significantly different trueness and precision results. [VS] and [OM] were more sensitive in terms of the scanned material. Clinical significanceThe latest IOSs showed the required accuracy for complete arch digital impressions in-vitro investigations. These findings should be implemented under conditions relevant to complete arch deviations, such as the construction of occlusal splints, analysis of occlusal relationships, and long-span restorations. Clinicians should be aware that the clinically acceptable threshold varies depending on the purpose of the IOS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.