Abstract

The medial patello-femoral ligament (MPFL) is considered the primary restraint against patellar dislocation and its reconstruction is indicated in recurrent patellar instability. An anatomical positioning of MPFL femoral insertion is recommended to achieve satisfactory clinical outcomes and prevent osteoarthritis (OA) due to an altered kinematics. The purpose of the study was first to assess the relationship between correct femoral tunnel position and better clinical outcomes and lower patellofemoral osteoarthritis rate. Second, correlation of outcomes with factors potentially affecting the results, such as the type of graft, patellar height and trochlear dysplasia. Fifty-three patients (58 knees) who underwent MPFL reconstruction between 2009 and 2018 by a senior knee surgeon were retrospectively evaluated. Knee radiographs were performed before surgery, 12months later and at last follow-up to assess trochlear dysplasia, patellar height and patellofemoral OA. The tibial tuberosity-trochlear groove (TT-TG) value was measured on a CT scan. The accuracy of graft positioning was evaluated on sagittal radiographs according to Schöttle et al. Subjective outcomes were collected before surgery, at 12months and at last follow-up using several validated scores. Forty-six patients (51 knees) with a mean age of 24.1 ± 7.4years were included in the study. Mean follow-up was 8.9 ± 2.1years. A significant improvement in all clinical scores was observed at 12months and final follow-up. Anatomic Insertion (AI) of reconstructed MPFL was considered optimal in 33 (64.7%) and sub-optimal in 18 (35.3%) patients. Sub-optimal AI resulted in lower Kujala, IKCD and higher VAS score (p < 0.01); moreover, for every 1mm distance in any direction from the ideal insertion, a decrease of 0.8 [95% CI (-1.4; -0.2)] in Kujala score and 0.8 [95% CI (-1.3; -0.3)] in IKDC was observed. At final follow-up, 8 patients presented patellofemoral OA Iwano grade 3 (15.7%): although that incidence did not correlate to graft positioning, the use the artificial ligament in all these cases appeared to be significant. The present study confirms the importance of an optimal anatomic femoral insertion in MPFL reconstruction, reporting a significant positive correlation between graft positioning and clinical outcome. No significant correlations were found between anatomic insertion and patello-femoral OA development. IV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.