Abstract
To determine the accuracy of T1-weighted fat-suppressed (FS) three-dimensional (3D) fast low-angle shot (FLASH) magnetic resonance (MR) imaging for the detection of articular cartilage abnormalities of the patellofemoral joint. Forty-one patients with suspected internal derangement of the knee were examined with a T1-weighted FS 3D FLASH sequence and subsequently underwent arthroscopy. The patellofemoral articular cartilage was graded blindly on both the MR and arthroscopic images with a modification of the Noyes classification scheme. For the detection of abnormal articular cartilage of the patellofemoral joint with the FS 3D FLASH sequence, sensitivity was 81%, specificity was 97%, and accuracy was 97%. Of the lesions detected on MR images, 77% were graded identically on MR and arthroscopic images. For the remaining 23%, MR imaging and arthroscopic ratings were within one grade of each other. T1-weighted FS 3D FLASH imaging is accurate for the detection and grading of articular cartilage abnormalities of the patellofemoral joint.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.