Abstract

Feeding high-quality colostrum is essential for calf health and future productivity. Therefore, accurate assessment of colostrum quality is a key component of dairy farm management plans. Direct and indirect methods are available for assessment of colostrum quality; however, the indirect methods are rapid, inexpensive, and can be performed under field settings. A hierarchical latent class model fit within a Bayesian framework was used to estimate the sensitivity (Se) and specificity (Sp) of the radial immunodiffusion (RID) assay, transmission infrared (TIR) spectroscopy, and digital Brix refractometer for the assessment of low-quality bovine colostrum in Atlantic Canada dairy herds. The secondary objective of the study was to describe the distribution of herd prevalence of low-quality colostrum. Colostrum quality of 591 samples from 42 commercial Holstein dairy herds in 4 Atlantic Canada provinces was assessed using RID, TIR spectroscopy, and digital Brix refractometer. The accuracy of all tests at different Brix value thresholds was estimated using Bayesian latent class models to obtain posterior estimates [medians and 95% Bayesian credibility intervals (95% BCI)] for each parameter. Using a threshold of <23% for digital Brix refractometer and <50 g/L for RID and TIR spectroscopy, median (95% BCI) Se estimates were 73.2 (68.4-77.7), 86.2 (80.6-91.0), and 91.9% (89.0-94.2), respectively. Median (95% BCI) Sp estimates were 85.2% (81.0-88.9) for digital Brix refractometer, 99.4% (97.0-100) for RID, and 90.7% (87.8-93.2) for TIR spectroscopy. Median (95% BCI) within-herd low-quality colostrum prevalence was estimated at 32.5% (27.9-37.4). In conclusion, using digital Brix refractometer at a Brix threshold of <23% could reduce feeding of low-quality colostrum to calves and improve colostrum and calf management practices in Atlantic Canada dairy herds. The TIR spectroscopy showed high Se in detection of low-quality colostrum. However, the RID assay, which is used as the reference test in several studies, showed limited Se for detection of low-quality colostrum.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.