Abstract

Pulmonary thromboembolism (PTE) may increase D-dimer and decrease fibrinogen levels. However, in settings such as intensive care units (ICU) and in long-term hospitalised patients, several factors may influence D-dimer and fibrinogen concentrations and make them unreliable indicators for the diagnosis of PTE. The aim of this study was to evaluate the accuracy of D-dimer:fibrinogen ratio (DDFR) for the diagnosis of PTE in ICU patients. ICU patients who were suspected of having a first PTE and had no history of using anti-coagulants and contraceptives were included in the study. Levels of D-dimer and fibrinogen were measured for each patient prior to any intervention. Angiography or CT angiography was done in order to establish a definite diagnosis for each patient. Suitable analytical tests were performed to compare means. Eighty-one patients were included in the study, of whom 41 had PTE and 40 did not. Mean values of D-dimer and fibrinogen were 3.97 ± 3.22 µg/ml and 560.6 ± 197.3 mg/dl, respectively. Significantly higher levels of D-dimer (4.65 ± 3.46 vs 2.25 ± 2.55 µg/ml, p = 0.006) and DDFR (0.913 ± 0.716 vs 483 ± 0.440 × 10-(3), p = 0.003) were seen in PTE patients than in those without PTE. Receiver operating characteristic (ROC) analysis showed a 70.3% sensitivity and 70.1% specificity with a D-dimer value of 2.43 µg/ml (AUC = 0.714, p = 0.002) as the best cut-off point; and a 70.3% sensitivity and 61.6% specificity with a DDFR value of 0.417 × 10-(3) (AUC = 0.710, p = 0.004) as the best cut-off point. In backward stepwise regression analysis, DDRF (OR = 0.72, p = 0.025), gender (OR = 0.76, p = 0.049) and white blood cell count (OR = 1.11, p = 0.373) were modelled (p = 0.029, R(2) = 0.577). For diagnosis of PTE, DDFR can be considered to have almost the same importance as D-dimer level. Moreover, it was possible to rule out PTE with only a D-dimer cut-off value < 0.43 mg/dl, without the use of DDFR. However, these values cannot be used as a replacement for angiography or CT angiography.

Highlights

  • Pulmonary thromboembolism (PTE) may increase D-dimer and decrease fibrinogen levels

  • It was possible to rule out PTE with only a D-dimer cut-off value < 0.43 mg/dl, without the use of D-dimer:fibrinogen ratio (DDFR)

  • These values cannot be used as a replacement for angiography or computed tomographic (CT) angiography

Read more

Summary

Introduction

Pulmonary thromboembolism (PTE) may increase D-dimer and decrease fibrinogen levels. In settings such as intensive care units (ICU) and in long-term hospitalised patients, several factors may influence D-dimer and fibrinogen concentrations and make them unreliable indicators for the diagnosis of PTE. The aim of this study was to evaluate the accuracy of D-dimer:fibrinogen ratio (DDFR) for the diagnosis of PTE in ICU patients. Methods: ICU patients who were suspected of having a first PTE and had no history of using anti-coagulants and contraceptives were included in the study. Higher levels of D-dimer (4.65 ± 3.46 vs 2.25 ± 2.55 μg/ml, p = 0.006) and DDFR (0.913 ± 0.716 vs 483 ± 0.440 × 10-3, p = 0.003) were seen in PTE patients than in those without PTE.

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.