Abstract
The management of circulating blood volume (BVc) is crucial in intensive care unit (ICU) patients. The purpose of this study was to verify the accuracy and precision of the carbon monoxide-labeled hemoglobin (CO-Hb) dilution method (CO method) by comparing it with the 51Cr-labeled erythrocyte dilution method (51Cr method) for the measurement of BVc. A prospective study was performed in 18 patients who underwent coronary artery bypass grafting (CABG) under mild hypothermic cardiopulmonary bypass (CPB). The BVc was measured by both the CO method and the 51Cr method at 24 hr after ICU admission in order to verify the accuracy and precision of the CO method. Paired data were assessed in absolute terms, and percentage errors were calculated by the degree of agreement. Small mean differences and standard deviations between the CO method and the 51Cr method (-70.2 +/-184.8 mL) and small percentage errors (-0.49+/-1.29%) indicated the accuracy and precision of the CO method, and a close correlation was observed (r = 0.97). The CO method can measure BVc with a similar degree of accuracy as the 51Cr method. It is simple, repeatable and safe without the risk of exposure to radioactivity in the ICU.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Canadian journal of anaesthesia = Journal canadien d'anesthesie
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.