Abstract
Statement of problemFabrication of conventional facial prostheses is a labor-intensive process which traditionally requires an impression of the facial defect and surrounding tissues. Inaccuracies occur during the facial moulage because of soft-tissue compression, the patient's reflex movements, or the lack of support for the impression material. A variety of 3D imaging techniques have been introduced during the production of facial prostheses. However, the accuracy of the different imaging techniques has not been evaluated sufficiently in this clinical context. PurposeThe purpose of this in vitro study was to compare the difference in accuracy of capturing oncology facial defects with multimodal image fusion and laser scanning against a cone beam computed tomography (CBCT) reference scan. Material and methodsTen gypsum casts of oncology facial defects were acquired. To produce reference models, a 3D volumetric scan was obtained using a CBCT scanner and converted into surface data using open-source medical segmentation software. This model was cropped to produce a CBCT mask using an open-source system for editing meshes. The multimodal image fusion model was created using stereophotogrammetry to capture the external facial features and a custom optical structured light scanner to record the defect. The gypsum casts were also scanned using a commercial 3D laser scanner to create the laser-scanned model. Analysis of the best fit of each experimental model to the CBCT mask was performed in MeshLab. The unsigned mean distance was used to measure the absolute deviation of each model from the CBCT mask. A paired-samples t test was conducted to compare the mean global deviation of the 2 imaging modalities from the CBCT masks (α=.05). ResultsA statistically significant difference was found in the mean global deviation between the multimodal imaging model (220 ±50 μm) and the laser-scanned model (170 ±70 μm); (t(9)=2.56, P=.031). The color error maps illustrated that the greatest error was located at sites distant to the prosthesis margins. ConclusionsThe laser-scanned models were more accurate; however, the mean difference of 50 μm is unlikely to be clinically significant. The laser scanner had limited viewing angles and a longer scan time which may limit its transferability to maxillofacial practice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.