Abstract
There is a substantial burden of occupational health effects from heat exposure. We sought to assess the accuracy of estimated core body temperature (CBTest) derived from an algorithm that uses sequential heart rate and initializing CBT, 1 compared with gastrointestinal temperature measured using more invasive ingestible sensors (CBTgi), among outdoor agricultural workers. We analyzed CBTest and CBTgi data from Washington State, USA, pear and apple harvesters collected across one work shift in 2015 (13,413 observations, 35 participants) using Bland Altman methods. The mean (standard deviation, range) CBTgi was 37.7 (0.4, 36.5–39.4)°C. Overall CBT bias (limits of agreement) was −0.14 (±0.76)°C. Biases ranged from −0.006 to −0.75 °C. The algorithm, which does not require the use of ingestible sensors, may be a practical tool in research among groups of workers for evaluating the effectiveness of interventions to prevent adverse occupational heat health effects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Archives of Environmental & Occupational Health
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.