Abstract
The accuracy of numerical finite-difference solutions to the one-way-coupled Eulerian partial differential equations for particle concentration in the presence of thermophoresis and diffusion is explored at different Schmidt numbers in laminar boundary-layer flow of a hot gas over a cold wall. Crank-Nicolson and MacCormack space-marching solutions to the coupled partial differential equations are compared with essentially exact solutions to the self-similar ordinary differential equation problem to determine the requirements for achieving accuracy in numerical solutions. When the diffusion sublayer at the wall is to be resolved, in flows laden with nanometer particles, the cell “Peclet” number referenced to the thermophoretic velocity and grid spacing in the wall-normal direction, and particle diffusion coefficient, serves as a criterion for the accuracy of space-marching solutions and determines the required number of wall-normal grid points, which is proportional to the particle Schmidt number. This cri...
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.