Abstract

Laser-induced breakdown spectroscopy (LIBS) is a potential technology for online coal property analysis, but successful quantitative measurement of calorific value using LIBS suffers from relatively low accuracy caused by the matrix effect. To solve this problem, the support vector machine (SVM) and the partial least square (PLS) were combined to increase the measurement accuracy of calorific value in this study. The combination model utilized SVM to classify coal samples into two groups according to their volatile matter contents to reduce the matrix effect, and then applied PLS to establish calibration models for each sample group respectively. The proposed model was applied to the measurement of calorific values of 53 coal samples, showing that the proposed model could greatly increase accuracy of the measurement of calorific values. Compared with the traditional PLS method, the coefficient of determination (R2) was improved from 0.93 to 0.97, the root-mean-square error of prediction was reduced from 1.68 MJ kg−1 to 1.08 MJ kg−1, and the average relative error was decreased from 6.7% to 3.93%, showing an overall improvement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.