Abstract

ObjectiveIn the paper laser scanning was used to evaluate, by indirect methods, the accuracy of computer-designed surgical guides in the oral implant supported rehabilitation of partially or completely edentulous patients. Materials and methodsFive implant supported rehabilitations for a total of twenty-three implants were carried out by computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. For all cases the surgical virtual planning, starting from 3D models obtained by dental scan DICOM data, was performed. The implants were inserted on the pre-surgical casts in the position defined in the virtual planning. These positions were acquired by three-dimensional optical laser scanning and compared with the laser scans of the intraoral impressions taken post-operatively. ResultsThe comparison between the post-surgical implant replica positions and the positions in the pre-operative cast, for the five patients, shows a maximum distance in the range 1.02–1.25mm, an average distance in the range 0.21–0.41mm and a standard deviation in the range 0.21–0.29mm. SignificanceThe results of this research demonstrate accurate transfer of implant replica position by virtual implant insertion into a pre-operative cast and a post-operative cast obtained from impressioning. In previous studies the evaluation of the implant positions have required a post-surgical CT scan. With the indirect methods by laser scanning technique, proposed in the paper, this extra radiation exposure of the patient can be eliminated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call