Abstract
BackgroundMultiparametric (mp) magnetic resonance imaging (MRI) has become an important tool for the detection of clinically significant prostate cancer. However, diagnostic accuracy is affected by variability between radiologists. ObjectiveTo determine the accuracy and variability in prostate mpMRI interpretation among radiologists, both individually and in teams, in a blinded fashion. Design, setting, and participantsA study cohort (n=32) was created from our prospective registry of patients who received prostate mpMRI with subsequent biopsy. The cohort was then independently reviewed by four radiologists of varying levels of experience, who assigned a Prostate Imaging Reporting and Data System (PI-RADS) classification, blinded to all clinical information. Consensus interpretation by teams of two radiologists was evaluated after a 12-wk wash-out period. Interpretive accuracy was calculated with various cutoffs for PI-RADS classification and Gleason score. Variability among individual radiologists and teams was calculated using the Fleiss kappa and intraclass correlation coefficient (ICC). Results and limitationsUsing PI-RADS 3+/Gleason 7+ (p<0.01) and PI-RADS 4+/Gleason 6+ (p=0.02) as cutoffs, significant differences in accuracy among the four radiologists were noted. At no cutoff for PI-RADS classification or Gleason score did a team read achieve higher accuracy than the most accurate radiologist. The kappa and ICC ranged from 0.22 to 0.29 for the individuals and from 0.16 to 0.21 for the teams (poor agreement). A larger sample size may be needed to adequately power differences in accuracy among individual radiologists. ConclusionsAt various cutoffs for PI-RADS classification and Gleason score, we find significant differences in individual radiologist accuracy, as well as a poor agreement among individual radiologists. Consensus interpretations—as teams of two radiologists—did not improve accuracy or reduce variability. Patient summaryThis study investigated radiologist variability and differences in accuracy using multiparametric magnetic resonance imaging for the diagnosis of prostate cancer. Despite attempts to standardize interpretation within the field, we found substantial variability and significant differences in accuracy among individual radiologists.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.