Abstract

The objective of this study is to determine the accuracy and safety of trans-pedicular screws' insertion in the thoracolumbar spine using a fluoroscopy-assisted surgical technique. We retrospectively evaluated all patients who underwent a postoperative computed tomography scan to assess the location of the pedicular screws following thoracolumbar spinal surgery, at the Mohammed Vth Military Training Hospital-Rabat, from January 2020 to April 2022. We used Gertzbein's classification to grade pedicular cortex breaches. A screw penetration greater than 4 mm (grades D-E) was considered critical and one less than 4 mm was classified as noncritical (grades A-C). A total of 122 screws inserted in the T1 to L5 vertebrae were included from 25 patients. The average age was 46 years old. Pathologies included degenerative disorders (5 patients), tumors (8 patients), and trauma (12 patients). All screws were inserted using lateral and anteroposterior fluoroscopic guidance. A total of 11 transpedicular screws breaches were identified. The breaches incidence was significantly higher in thoracic pedicles (8 screws) than in lumbar pedicles (3 screws). Of these, three critical cases occurred in two patients and one of them required reintervention. The remaining eight exceedances were not critical and were closely monitored and followed up. Transpedicular screws fluoroscopy-assisted surgical fixation can be performed for the stabilization of the thoracolumbar spine with satisfactory safety and precision.