Abstract

BackgroundPoor rotation of the femoral component in total knee arthroplasty (TKA) can result in various postoperative complications, underscoring the critical importance of preoperative planning.PurposeTo improve the accuracy of femoral component positioning during TKA, this study compared the accuracy and repeatability of different two-dimensional (2D) computed tomography (CT) measurement methods for measuring the posterior condylar angle (PCA) in preoperative TKA planning.MethodsA retrospective analysis was conducted on 75 patients (150 knees) who underwent bilateral lower extremity computed tomography angiography (CTA) at Fuyang People's Hospital from January 2021 to July 2021. Three different methods were used to measure the PCA based on 2D CT images (axial CT slices) and three-dimensional(3D) models (femoral models reconstructed from CT data) in this study. Method 1: Single-plane 2D CT measurement, measuring PCA in the most obvious single-plane CT slice of the surgical transepicondylar axis (sTEA); Method 2: multi-plane 2D CT measurement, identifying and locating anatomical landmarks in multiple 2D CT slices and measuring PCA; Method 3: 3D model measurement, measuring PCA in the reconstructed femur 3D model. Compare the differences in PCA measurements between the three measurement methods. A positive PCA measurement was recorded when the sTEA was externally rotated relative to the posterior condylar line (PCL). Any difference exceeding 3° between the PCA measurement in the 2D CT and the PCA reference value in the 3D model was classified as an outlier. The intraclass correlation coefficient (ICC) and Bland–Altman method were utilized to assess the intra- and inter-observer reproducibility of the three measurement methods.ResultsThe PCA measurement in the single-plane 2D CT was 1.91 ± 1.94°, with a measurement error of − 1.22 ± 1.32° and 12.7% of outlier values. In the multi-plane 2D CT, the PCA measurement was 2.96 ± 1.68°, with a measurement error of -0.15 ± 0.91° and 6.0% of outlier values. The PCA measurement in the 3D model was 3.12 ± 1.69°. The PCA measurement in single-plane 2D CT was notably smaller than that in multi-plane 2D CT and 3D models, with no significant difference between the latter two. The multi-plane 2D CT showed significantly lower measurement error and outlier values than the single-plane 2D CT. All three PCA measurement methods exhibited high reproducibility (ICC: 0.93 ~ 0.97).ConclusionsUsing of multi-plane 2D CT for measuring PCA in preoperative planning of TKA has high reproducibility and accuracy, with fewer outlier values. We recommend preoperative measurement of PCA using muti-plane 2D CT to improve the accuracy of positioning the femoral component rotational alignment during surgery.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call