Abstract

Our purpose was to compare the accuracy and reliability of linear measurements for Le Fort I osteotomy using volume rendering software. We studied 11 dried skulls and used cone-beam computed tomography (CT) to generate 3-dimensional images. Linear measurements were based on craniometric anatomical landmarks that were predefined as specifically used for Le Fort I osteotomy, and identified twice each by 2 radiologists, independently, using Dolphin imaging version 11.5.04.35. A third examiner then made physical measurements using digital calipers. There was a significant difference between Dolphin imaging and the gold standard, particularly in the pterygoid process. The largest difference was 1.85mm (LLpPtg L). The mean differences between the physical and the 3-dimensional linear measurements ranged from −0.01 to 1.12mm for examiner 1, and 0 to 1.85mm for examiner 2. Interexaminer analysis ranged from 0.51 to 0.93. Intraexaminer correlation coefficients ranged from 0.81 to 0.96 and 0.57 to 0.92, for examiners 1 and 2, respectively. We conclude that the Dolphin imaging should be used sparingly during Le Fort I osteotomy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.