Abstract
Digital templating has been used as a method of reducing hospital costs by eliminating the need for acetate films. Digital templating techniques have been used for preoperative planning for total hip arthroplasty (THA). Fifty-four patients who underwent THA were selected for the study. Templating was performed using acetate templating overlays and digital templating software. Acetabular component sizes were accurate in 96% of patients using the acetate method and in 93% using the digital method. Femoral component sizes were accurate in 80% in the acetate method and 74% in the digital method. Digital templating is safe and effective for preoperative planning for THA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.