Abstract

The performance of urine Xpert MTB/RIF Ultra (Xpert Ultra) for pulmonary TB diagnosis is unknown. HIV-positive and HIV-negative adults were enrolled at two health facilities in Kampala, Uganda. We compared the accuracy of urine Xpert Ultra and Determine TB-LAM in reference to sputum-based testing (positive Xpert MTB/RIF or culture), and assessed incremental yield. Urine Xpert Ultra had low sensitivity (17.2%, 95% CI 12.3–23.2) but high specificity (98.1%, 95% CI 94.4–99.6). Sensitivity reached 50.0% (95% CI 28.2–71.8) among HIV-positive patients with CD4 <100 cells/μL. Compared to Determine TB-LAM, urine Xpert Ultra was 9.4% (95% CI 3.8–14.9, P = 0.01) more sensitive, and 17.2% (95% CI 4.5–29.8, P = 0.01) more sensitive among HIV-positive patients. However, the incremental sensitivity of urine Xpert Ultra relative to sputum Xpert MTB/RIF was only 1% (95% CI -0.9 to 2.8). Urine Xpert Ultra could be an alternative for patients with advanced HIV infection unable to produce sputum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.