Abstract
To determine the accuracy of CT-guided percutaneous transthoracic needle lung biopsy (PTNB) for the diagnosis of malignancy and the associated complication rates in patients with idiopathic pulmonary fibrosis (IPF). This retrospective study included 91 CT-guided PTNBs performed in 80 patients with IPF from April 2003 through December 2016. Data regarding patients, target lesions, procedures, complications, and pathological reports were collected, and the final diagnosis was made. The diagnostic accuracy, sensitivity, specificity, percentage of nondiagnostic results, and complication rates were determined. Multivariable logistic regression analyses were performed to identify risk factors for nondiagnostic results and major complications. Three biopsies (technical failure [n = 2] and undetermined final diagnosis [n = 1]) were excluded from the diagnostic accuracy calculation. The diagnostic accuracy, sensitivity, and specificity were 89% (78/88), 90% (62/69), and 84% (16/19), respectively. The percentage of nondiagnostic results was 34% (30/88). Lesion size ≤ 3 cm (odds ratio [OR], 8.8; 95% confidence interval [CI], 2.5-31.2; p = 0.001) and needle tip placement outside the target lesion (OR, 13.7; 95% CI, 1.4-132.2; p = 0.02) were risk factors for nondiagnostic results. The overall and major complication rates were 51% (46/91) and 12% (11/91), respectively. The presence of honeycombing along the path of the needle (OR, 11.2; 95% CI, 1.4-89.1; p = 0.02) was an independent risk factor for major complications. CT-guided PTNB shows a relatively reasonable accuracy in diagnosing malignancy in patients with IPF. The complication rate may be high, especially when the needle passes through honeycomb lesions. • In patients with idiopathic pulmonary fibrosis (IPF), CT-guided percutaneous transthoracic needle lung biopsy (PTNB) showed a relativelyreasonable accuracy for the diagnosis of malignancy. • Target lesion size ≤ 3 cm and biopsy needle tip placement outside the target lesion were risk factors for nondiagnostic results of CT-guided PTNB. • The complication rate may be high, especially in cases where the biopsy needle passes through honeycomb lesions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.