Abstract

Several reports have shown a coincidence relationship between perforators and acupoints. However, there have been few previous reports of objective experimental methods to verify the reliability of the accuracy of acupoint location (APL) with nearby perforators. This research aimed to determine the internal agreement of the APL of five acupuncturists and to analyze the coincidence rate of acupoints with nearby perforators. Three two healthy volunteers were recruited with the inclusion and exclusion criteria. Three TCM clinical physicians determined acupoints in areas of the lower limb of participants. Two microsurgeons sketched corresponding regions based on the most common skin flap operation sites, located bone markers, and drew the skin flap axis. Doppler ultrasound was used to mark the perforator point and the distances measured for both points. There is no significant difference in the distance between the acupoints and perforators localization in different groups, and there are significant differences between the angle formed by acupoints and penetrators in all groups. All the points located by the traditional Chinese medicine (TCM) therapists are distributed around the dot. The distance between the coordinate point (A-B) of Wēnliū (LI7) localization is the largest, reaching 16.6 mm. The accuracy of the acupoint location of each physician is limited by the clinical experience of physicians, and the difference among them is significant. There is a certain correspondence between the location of acupoints and perforators, which needs further studies to confirm.