Abstract

The safety report of the TRIGA Mark II reactor in Vienna includes three accident scenarios and their deterministic dose consequences to the environment. The destruction of the cladding of the most activated fuel element, the destruction of all fuel elements and a plane crash were considered scenarios in that report. The calculations were made in 1978 with the software program named STRISK. In this paper, the program package PC Cosyma was applied on the TRIGA Mark II reactor in Vienna and the deterministic consequences of the scenarios to the environment were updated. The fission product inventories of all fuel elements were calculated with ORIGEN2. To get meteorological data of the atmospheric condition around the release area, a weather station was installed. The release parameters were taken from the safety report or were replaced by worst case parameters. This paper focuses on two accident scenarios: the destruction of the cladding of the fuel element with the highest activity content and the case of a large plane crash. The current accident scenarios show good agreement with the calculations from 1978, hence no technical modifications in the safety report of the TRIGA reactor Vienna were necessary. Even in the very worst case scenario – complete destruction of all fuel elements in a large plane crash – the expected doses in the Atominstitut's neighborhood remain moderate.