The winding insulation of low-voltage induction motors in adjustable-speed drive systems with voltage-fed inverters are substantially stressed by the uneven voltage distribution and excessive voltage stress (dv/dt), which result in the premature insulation breakdown. This paper describes test results of the insulation characteristics of a 5 HP, 380 V induction motors for inverter applications. Eight different types of insulation techniques are applied to 40 induction motors respectively. Insulation characteristics are compared with respect to partial discharge, capacitance, current, and dissipation factor tests. Also, the insulation breakdown tests by high voltage pulses are performed and the corresponding breakdown voltages are obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.