Abstract

In the frame of the toroidal pump limiter fabrication for Tore Supra, CEA developed a large experience of infrared test for acceptance of high heat flux components armoured with carbon fibre composite flat tiles. The test is based on a thermal transient induced by an alternative hot/cold water flow in the heat sink structure. The tile surface temperature transients are compared with those of a reference element, the maximum difference for each tile leading to a value called Δ T ref_max. This method is proposed for the commissioning of plasma facing components for the ITER divertor vertical target. This paper describes the determination of the best acceptance criteria for the “monoblock” geometry of the carbon part. First, it has been shown that the location and the extension of the defects could reliably be determined by monitoring both top and lateral surfaces during the test. Second, it was possible to fix an acceptance method based on Δ T ref_max. Samples with calibrated defects are now under fabrication to validate the results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.