Abstract

Accelerator mass spectrometry (AMS) is an ultrasensitive technique to detect radiolabeled compounds. We administered a microdose (100 µg) of (14)C-labeled zidovudine (ZDV) with or without a standard unlabeled dose (300 mg) to healthy volunteers. Intracellular ZDV-triphosphate (ZDV-TP) concentration was measured using AMS and liquid chromatography-tandem mass spectrometry (LC/MS/MS). AMS analysis yielded excellent concordance with LC/MS/MS and was 30,000-fold more sensitive. The kinetics of intracellular ZDV-TP formation changed several-fold over the dose range studied (100 µg-300 mg). AMS holds promise as a tool for quantifying intracellular drug metabolites and other biomediators in vivo.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.